Colorectal cancer represents a global health burden, being the third most frequently diagnosed cancer worldwide, accounting for about 1.9 million new cases annually, and the second leading cause of cancer-related deaths. This highlights the need for innovative and effective methods for cancer detection, improving current diagnostic approaches. In this feasibility study, two nanostructured chemoresistive gas sensors based on tin oxide–titanium oxide composites were selected to detect the metabolic patterns associated with human healthy and colorectal cancer tissues, collected from 26 patients. To further validate the biopsy-derived results, the sensors were tested on two colorectal cancer-derived cell lines, namely Caco-2 and RKO. Both sensors were able to discriminate between healthy and tumor samples by comparing the mean sensor responses, using the paired t-test (p-value = 0.00018), and by using an LDA, achieving a cross-validated accuracy of 0.73. Moreover, the ROC analysis performed on the data projected along the discriminant direction led to an AUC of 0.83. Finally, the sensors exhibited distinct response profiles to Caco-2 and RKO exhalations, as expected given their different biological features. As a proof-of-feasibility study, these findings demonstrate that these sensors could capture a characteristic volatile fingerprint distinguishing the samples, although they cannot identify the specific cancer metabolites.

Nanostructured Tin- and Titanium-Based Chemoresistive Sensors for Detecting Volatile Fingerprints from Colorectal Cancer Biopsies and Cell Lines

Astolfi, Michele
Primo
;
Masin, Martina
Secondo
;
Anfuso, Antonio;Malagu', Cesare;Anania, Gabriele;Benedusi, Mascia;Valacchi, Giuseppe
Penultimo
;
Rispoli, Giorgio
Ultimo
2026

Abstract

Colorectal cancer represents a global health burden, being the third most frequently diagnosed cancer worldwide, accounting for about 1.9 million new cases annually, and the second leading cause of cancer-related deaths. This highlights the need for innovative and effective methods for cancer detection, improving current diagnostic approaches. In this feasibility study, two nanostructured chemoresistive gas sensors based on tin oxide–titanium oxide composites were selected to detect the metabolic patterns associated with human healthy and colorectal cancer tissues, collected from 26 patients. To further validate the biopsy-derived results, the sensors were tested on two colorectal cancer-derived cell lines, namely Caco-2 and RKO. Both sensors were able to discriminate between healthy and tumor samples by comparing the mean sensor responses, using the paired t-test (p-value = 0.00018), and by using an LDA, achieving a cross-validated accuracy of 0.73. Moreover, the ROC analysis performed on the data projected along the discriminant direction led to an AUC of 0.83. Finally, the sensors exhibited distinct response profiles to Caco-2 and RKO exhalations, as expected given their different biological features. As a proof-of-feasibility study, these findings demonstrate that these sensors could capture a characteristic volatile fingerprint distinguishing the samples, although they cannot identify the specific cancer metabolites.
2026
Astolfi, Michele; Masin, Martina; Anfuso, Antonio; Malagu', Cesare; Anania, Gabriele; Benedusi, Mascia; Valacchi, Giuseppe; Rispoli, Giorgio
File in questo prodotto:
File Dimensione Formato  
ijms-27-06647-v2.pdf

accesso aperto

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 18.26 MB
Formato Adobe PDF
18.26 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2643010
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact