Background: In the phase 3 MANDALA trial, as-needed albuterol-budesonide pressurized metered-dose inhaler significantly reduced severe exacerbation risk vs as-needed albuterol in patients with moderate-to-severe asthma receiving inhaled corticosteroid-containing maintenance therapy. This study (DENALI) was conducted to address the US Food and Drug Administration combination rule, which requires a combination product to demonstrate that each component contributes to its efficacy. Research question: Do both albuterol and budesonide contribute to the efficacy of the albuterol-budesonide combination pressurized metered-dose inhaler in patients with asthma? Study design and methods: This phase 3 double-blind trial randomized patients aged ≥ 12 years with mild-to-moderate asthma 1:1:1:1:1 to four-times-daily albuterol-budesonide 180/160 μg or 180/80 μg, albuterol 180 μg, budesonide 160 μg, or placebo for 12 weeks. Dual-primary efficacy end points included change from baseline in FEV1 area under the curve from 0 to 6 h (FEV1 AUC0-6h) over 12 weeks (assessing albuterol effect) and trough FEV1 at week 12 (assessing budesonide effect). Results: Of 1,001 patients randomized, 989 were ≥ 12 years old and evaluable for efficacy. Change from baseline in FEV1 AUC0-6h over 12 weeks was greater with albuterol-budesonide 180/160 μg vs budesonide 160 μg (least-squares mean [LSM] difference, 80.7 [95% CI, 28.4-132.9] mL; P = .003). Change in trough FEV1 at week 12 was greater with albuterol-budesonide 180/160 and 180/80 μg vs albuterol 180 μg (LSM difference, 132.8 [95% CI, 63.6-201.9] mL and 120.8 [95% CI, 51.5-190.1] mL, respectively; both P < .001). Day 1 time to onset and duration of bronchodilation with albuterol-budesonide were similar to those with albuterol. The albuterol-budesonide adverse event profile was similar to that of the monocomponents. Interpretation: Both monocomponents contributed to albuterol-budesonide lung function efficacy. Albuterol-budesonide was well tolerated, even at regular, relatively high daily doses for 12 weeks, with no new safety findings, supporting its use as a novel rescue therapy.

Albuterol-Budesonide Pressurized Metered Dose Inhaler in Patients With Mild-to-Moderate Asthma: Results of the DENALI Double-Blind Randomized Controlled Trial

Papi, Alberto
Ultimo
2023

Abstract

Background: In the phase 3 MANDALA trial, as-needed albuterol-budesonide pressurized metered-dose inhaler significantly reduced severe exacerbation risk vs as-needed albuterol in patients with moderate-to-severe asthma receiving inhaled corticosteroid-containing maintenance therapy. This study (DENALI) was conducted to address the US Food and Drug Administration combination rule, which requires a combination product to demonstrate that each component contributes to its efficacy. Research question: Do both albuterol and budesonide contribute to the efficacy of the albuterol-budesonide combination pressurized metered-dose inhaler in patients with asthma? Study design and methods: This phase 3 double-blind trial randomized patients aged ≥ 12 years with mild-to-moderate asthma 1:1:1:1:1 to four-times-daily albuterol-budesonide 180/160 μg or 180/80 μg, albuterol 180 μg, budesonide 160 μg, or placebo for 12 weeks. Dual-primary efficacy end points included change from baseline in FEV1 area under the curve from 0 to 6 h (FEV1 AUC0-6h) over 12 weeks (assessing albuterol effect) and trough FEV1 at week 12 (assessing budesonide effect). Results: Of 1,001 patients randomized, 989 were ≥ 12 years old and evaluable for efficacy. Change from baseline in FEV1 AUC0-6h over 12 weeks was greater with albuterol-budesonide 180/160 μg vs budesonide 160 μg (least-squares mean [LSM] difference, 80.7 [95% CI, 28.4-132.9] mL; P = .003). Change in trough FEV1 at week 12 was greater with albuterol-budesonide 180/160 and 180/80 μg vs albuterol 180 μg (LSM difference, 132.8 [95% CI, 63.6-201.9] mL and 120.8 [95% CI, 51.5-190.1] mL, respectively; both P < .001). Day 1 time to onset and duration of bronchodilation with albuterol-budesonide were similar to those with albuterol. The albuterol-budesonide adverse event profile was similar to that of the monocomponents. Interpretation: Both monocomponents contributed to albuterol-budesonide lung function efficacy. Albuterol-budesonide was well tolerated, even at regular, relatively high daily doses for 12 weeks, with no new safety findings, supporting its use as a novel rescue therapy.
2023
Chipps, Bradley E; Israel, Elliot; Beasley, Richard; Panettieri, Reynold A; Albers, Frank C; Rees, Robert; Dunsire, Lynn; Danilewicz, Anna; Johnsson, ...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0012369223004634-main.pdf

accesso aperto

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 603.7 kB
Formato Adobe PDF
603.7 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2522570
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact