The aim of this survey, which was open to all Italian cardiologists involved in arrhythmia, was to assess common practice regarding sedation and analgesia in interventional electrophysiology procedures in Italy. The survey consisted of 28 questions regarding the approach to sedation used for elective direct-current cardioversion (DCC), subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, atrial fibrillation (AF) ablation, ventricular tachycardia (VT) ablation, and transvenous lead extraction procedures. A total of 105 cardiologists from 92 Italian centres took part in the survey. The rate of centres where DCC, S-ICD implantation, AF ablation, VT ablation and lead extraction procedures were performed without anaesthesiologic assistance was 60.9%, 23.6%, 51.2%, 37.3%, and 66.7%, respectively. When these procedures were performed without anaesthesiologic assistance, the drugs (in addition to local anaesthetics) commonly administered were benzodiazepines (from 64.3% to 79.6%), opioids (from 74.4% to 88.1%), and general anaesthetics (from 7.1% to 30.4%). Twenty-three (21.9%) of the 105 cardiologists declared that they routinely administered propofol, without the supervision of an anaesthesiologist, in at least one of the above-mentioned procedures. In current Italian clinical practice, there is a lack of uniformity in the sedation/analgesia approach used in interventional electrophysiology procedures.

The Practice of Deep Sedation in Electrophysiology and Cardiac Pacing Laboratories: Results of an Italian Survey Promoted by the AIAC (Italian Association of Arrhythmology and Cardiac Pacing)

Bertini M.;Notarstefano P.;
2021

Abstract

The aim of this survey, which was open to all Italian cardiologists involved in arrhythmia, was to assess common practice regarding sedation and analgesia in interventional electrophysiology procedures in Italy. The survey consisted of 28 questions regarding the approach to sedation used for elective direct-current cardioversion (DCC), subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, atrial fibrillation (AF) ablation, ventricular tachycardia (VT) ablation, and transvenous lead extraction procedures. A total of 105 cardiologists from 92 Italian centres took part in the survey. The rate of centres where DCC, S-ICD implantation, AF ablation, VT ablation and lead extraction procedures were performed without anaesthesiologic assistance was 60.9%, 23.6%, 51.2%, 37.3%, and 66.7%, respectively. When these procedures were performed without anaesthesiologic assistance, the drugs (in addition to local anaesthetics) commonly administered were benzodiazepines (from 64.3% to 79.6%), opioids (from 74.4% to 88.1%), and general anaesthetics (from 7.1% to 30.4%). Twenty-three (21.9%) of the 105 cardiologists declared that they routinely administered propofol, without the supervision of an anaesthesiologist, in at least one of the above-mentioned procedures. In current Italian clinical practice, there is a lack of uniformity in the sedation/analgesia approach used in interventional electrophysiology procedures.
2021
Palmisano, P.; Ziacchi, M.; Angeletti, A.; Guerra, F.; Forleo, G. B.; Bertini, M.; Notarstefano, P.; Accogli, M.; Lavalle, C.; Bisignani, G.; Landolin...espandi
File in questo prodotto:
File Dimensione Formato  
jcm-10-05035.pdf

accesso aperto

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 5.5 MB
Formato Adobe PDF
5.5 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2471371
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact