Background-3D transesophageal echocardiography (TEE) may provide more accurate aortic annular and left ventricular outflow tract (LVOT) dimensions and geometries compared with 2D TEE. We assessed agreements between 2D and 3D TEE measurements with multislice computed tomography (MSCT) and changes in annular/LVOT areas and geometries after transcatheter aortic valve implantations (TAVI). Methods and Results-Two-dimensional circular (π×r 2), 3D circular, and 3D planimetered annular and LVOT areas by TEE were compared with "gold standard" MSCT planimetered areas before TAVI. Mean MSCT planimetered annular area was 4.65±0.82 cm 2 before TAVI. Annular areas were underestimated by 2D TEE circular (3.89±0.74 cm 2, P<0.001), 3D TEE circular (4.06±0.79 cm 2, P<0.001), and 3D TEE planimetered annular areas (4.22±0.77 cm 2, P<0.001). Mean MSCT planimetered LVOT area was 4.61 ± 1.20 cm 2 before TAVI. LVOT areas were underestimated by 2D TEE circular (3.41 ±0.89 cm 2, P<0.001), 3D TEE circular (3.89±0.94 cm 2, P<0.001), and 3D TEE planimetered LVOT areas (4.31 ±1.15 cm 2, P<0.001). Three-dimensional TEE planimetered annular and LVOT areas had the best agreement with respective MSCT planimetered areas. After TAVI, MSCT planimetered (4.65±0.82 versus 4.20±0.46 cm 2, P<0.001) and 3D TEE planimetered (4.22±0.77 versus 3.62±0.43 cm 2, P<0.001) annular areas decreased, whereas MSCT planimetered (4.61 ±1.20 versus 4.84±1.17 cm 2, P=0.002) and 3D TEE planimetered (4.31 ±1.15 versus 4.55±1.21 cm 2, P<0.001) LVOT areas increased. Aortic annulus and LVOT became less elliptical after TAVI. Conclusions-Before TAVI, 2D and 3D TEE aortic annular/LVOT circular geometric assumption underestimated the respective MSCT planimetered areas. After TAVI, 3D TEE and MSCT planimetered annular areas decreased as it assumes the internal dimensions of the prosthetic valve. However, planimetered LVOT areas increased due to a more circular geometry. © 2010 American Heart Association, Inc.

Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2-and 3-dimensional transesophageal echocardiography and multislice computed tomography

Bertini M.;
2010

Abstract

Background-3D transesophageal echocardiography (TEE) may provide more accurate aortic annular and left ventricular outflow tract (LVOT) dimensions and geometries compared with 2D TEE. We assessed agreements between 2D and 3D TEE measurements with multislice computed tomography (MSCT) and changes in annular/LVOT areas and geometries after transcatheter aortic valve implantations (TAVI). Methods and Results-Two-dimensional circular (π×r 2), 3D circular, and 3D planimetered annular and LVOT areas by TEE were compared with "gold standard" MSCT planimetered areas before TAVI. Mean MSCT planimetered annular area was 4.65±0.82 cm 2 before TAVI. Annular areas were underestimated by 2D TEE circular (3.89±0.74 cm 2, P<0.001), 3D TEE circular (4.06±0.79 cm 2, P<0.001), and 3D TEE planimetered annular areas (4.22±0.77 cm 2, P<0.001). Mean MSCT planimetered LVOT area was 4.61 ± 1.20 cm 2 before TAVI. LVOT areas were underestimated by 2D TEE circular (3.41 ±0.89 cm 2, P<0.001), 3D TEE circular (3.89±0.94 cm 2, P<0.001), and 3D TEE planimetered LVOT areas (4.31 ±1.15 cm 2, P<0.001). Three-dimensional TEE planimetered annular and LVOT areas had the best agreement with respective MSCT planimetered areas. After TAVI, MSCT planimetered (4.65±0.82 versus 4.20±0.46 cm 2, P<0.001) and 3D TEE planimetered (4.22±0.77 versus 3.62±0.43 cm 2, P<0.001) annular areas decreased, whereas MSCT planimetered (4.61 ±1.20 versus 4.84±1.17 cm 2, P=0.002) and 3D TEE planimetered (4.31 ±1.15 versus 4.55±1.21 cm 2, P<0.001) LVOT areas increased. Aortic annulus and LVOT became less elliptical after TAVI. Conclusions-Before TAVI, 2D and 3D TEE aortic annular/LVOT circular geometric assumption underestimated the respective MSCT planimetered areas. After TAVI, 3D TEE and MSCT planimetered annular areas decreased as it assumes the internal dimensions of the prosthetic valve. However, planimetered LVOT areas increased due to a more circular geometry. © 2010 American Heart Association, Inc.
2010
Ng, A. C. T.; Delgado, V.; Van Der Kley, F.; Shanks, M.; Van De Veire, N. R. L.; Bertini, M.; Nucifora, G.; Van Bommel, R. J.; Tops, L. F.; De Weger, A.; Tavilla, G.; De Roos, A.; Kroft, L. J.; Leung, D. Y.; Schuijf, J.; Schalij, M. J.; Bax, J. J.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2437638
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 47
  • Scopus 339
  • ???jsp.display-item.citation.isi??? 286
social impact