Persistence of a left superior vena cava (LSVC) has been reported in 0.3%-0.4% of candidates for pacemaker (PM) or cardioverter-defibrillator (ICD) implantation. The aim of the study was to evaluate the clinical implications of LSVC persistence for proper device performance. We observed the prevalence of LSVC during a 15-year period. A total of 2077 consecutive patients underwent PM implantation over a 15-year period: 7 had persistent LSVCs (0.34%). Among 599 patients undergoing ICD implantation, 4 LSVCs (0.66%) were observed. Overall LSVC persistence was found in 11/2676 (0.41%) patients. The right superior vena cava was absent in 4/11 (36%) patients. The leads were placed from the left subclavian approach in 5/7 PM patients: 2 received an elective right sided approach due to physician preference. All ICD patients had the device placed left pectoral with a single-coil lead: defibrillation therapy was effective in the long term in all but one patient, who required the addition of a subcutaneous array. Left superior vena cava persistence in PM/ICD patients is similar to the general population (0.41% in our study). The left-sided implant may be skill-demanding during lead placement; however, this task can be accomplished in the majority of cases, with a reliable outcome in the short term and appropriate device performance at follow-up. © Springer Japan 2009.

Clinical implications of left superior vena cava persistence in candidates for pacemaker or cardioverter-defibrillator implantation

Bertini M.;
2009

Abstract

Persistence of a left superior vena cava (LSVC) has been reported in 0.3%-0.4% of candidates for pacemaker (PM) or cardioverter-defibrillator (ICD) implantation. The aim of the study was to evaluate the clinical implications of LSVC persistence for proper device performance. We observed the prevalence of LSVC during a 15-year period. A total of 2077 consecutive patients underwent PM implantation over a 15-year period: 7 had persistent LSVCs (0.34%). Among 599 patients undergoing ICD implantation, 4 LSVCs (0.66%) were observed. Overall LSVC persistence was found in 11/2676 (0.41%) patients. The right superior vena cava was absent in 4/11 (36%) patients. The leads were placed from the left subclavian approach in 5/7 PM patients: 2 received an elective right sided approach due to physician preference. All ICD patients had the device placed left pectoral with a single-coil lead: defibrillation therapy was effective in the long term in all but one patient, who required the addition of a subcutaneous array. Left superior vena cava persistence in PM/ICD patients is similar to the general population (0.41% in our study). The left-sided implant may be skill-demanding during lead placement; however, this task can be accomplished in the majority of cases, with a reliable outcome in the short term and appropriate device performance at follow-up. © Springer Japan 2009.
2009
Biffi, M.; Bertini, M.; Ziacchi, M.; Martignani, C.; Valzania, C.; Diemberger, I.; Branzi, A.; Boriani, G.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2437375
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 41
social impact