To determine the accuracy of non-contact tonometry in patients with corneas thinned by photorefractive keratectomy, the authors measured the intraocular pressure with a non-contact tonometer and the corneal thickness with an ultrasonic pachymeter in 47 patients before and 9 months after photorefractive keratectomy. The patients were divided into three groups according to the degree of treatment: group I between 1 and 5 diopters (14 eyes), group II between 6 and 10 diopters (18 eyes), group III between 11 and 15 diopters (15 eyes). In the first group of patients mean intraocular pressure was 16.1 (± 3.85) mm Hg before surgery, and 13.2 (± 3.14) mm Hg after surgery with a significant difference (p = 0.0027). In the second group of patients mean intraocular pressure was 16.0 (± 4.13) mm Hg before surgery and 13.0 (± 3.0) mm Hg after surgery with a significant difference (p = 0.0045). In the third group of patients mean intraocular pressure was 17.7 (± 3.8) mm Hg before surgery and 12.4 (±...

Non-contact tonometry in patients that underwent photorefractive keratectomy

SEBASTIANI, Adolfo
1997

Abstract

To determine the accuracy of non-contact tonometry in patients with corneas thinned by photorefractive keratectomy, the authors measured the intraocular pressure with a non-contact tonometer and the corneal thickness with an ultrasonic pachymeter in 47 patients before and 9 months after photorefractive keratectomy. The patients were divided into three groups according to the degree of treatment: group I between 1 and 5 diopters (14 eyes), group II between 6 and 10 diopters (18 eyes), group III between 11 and 15 diopters (15 eyes). In the first group of patients mean intraocular pressure was 16.1 (± 3.85) mm Hg before surgery, and 13.2 (± 3.14) mm Hg after surgery with a significant difference (p = 0.0027). In the second group of patients mean intraocular pressure was 16.0 (± 4.13) mm Hg before surgery and 13.0 (± 3.0) mm Hg after surgery with a significant difference (p = 0.0045). In the third group of patients mean intraocular pressure was 17.7 (± 3.8) mm Hg before surgery and 12.4 (±...
1997
Cennamo, G; Rosa, N; LA RANA, A; Bianco, S; Sebastiani, Adolfo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1208575
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 37
social impact