The study aimed at the development of a clinically applicable methodology that could: (1) discriminate transient evoked otoacoustic emission (TEOAE) recordings from normal hearing or hearing impaired individuals; (2) classify the nature of the hearing loss as conductive or as cochlear, and (3) define clear-cut TEOAE clinical criteria. A classification algorithm based on a multivariate discriminant analysis of fast Fourier transform data from recordings evoked by click stimuli of 50 +/- 2, 62 +/- 2, 68 +/- 2 and 80 +/- 2 dB SPL was used to discriminate 302 normal subjects from 383 subjects suffering from mild to moderate hearing losses. The best discriminant model (QDF80) produced a sensitivity of 93.8% and a specificity of 79.4%. When extra correlation criteria were serially applied to the classification outcome, the specificity was increased to 85.3%, but the sensitivity was marginally decreased to 91.7%. The classification of the correctly identified hearing-impaired cases yielded 93.8% identification of conductive and 75.1% identification of cochlear cases. A sensitivity analysis of the misclassified hearing-impaired cases suggested that the TEOAE spectra are well correlated with the 2-kHz but poorly correlated with the 4-kHz octave frequency.

Clinical applicability of transient evoked otoacoustic emissions: Identification and classification of hearing loss

HATZOPOULOS, Stavros;PROSSER, Silvano;ROSIGNOLI, Monica;MARTINI, Alessandro
1998

Abstract

The study aimed at the development of a clinically applicable methodology that could: (1) discriminate transient evoked otoacoustic emission (TEOAE) recordings from normal hearing or hearing impaired individuals; (2) classify the nature of the hearing loss as conductive or as cochlear, and (3) define clear-cut TEOAE clinical criteria. A classification algorithm based on a multivariate discriminant analysis of fast Fourier transform data from recordings evoked by click stimuli of 50 +/- 2, 62 +/- 2, 68 +/- 2 and 80 +/- 2 dB SPL was used to discriminate 302 normal subjects from 383 subjects suffering from mild to moderate hearing losses. The best discriminant model (QDF80) produced a sensitivity of 93.8% and a specificity of 79.4%. When extra correlation criteria were serially applied to the classification outcome, the specificity was increased to 85.3%, but the sensitivity was marginally decreased to 91.7%. The classification of the correctly identified hearing-impaired cases yielded 93.8% identification of conductive and 75.1% identification of cochlear cases. A sensitivity analysis of the misclassified hearing-impaired cases suggested that the TEOAE spectra are well correlated with the 2-kHz but poorly correlated with the 4-kHz octave frequency.
1998
Hatzopoulos, Stavros; Prosser, Silvano; Mazzoli, M; Rosignoli, Monica; Martini, Alessandro
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/533781
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact