To investigate the de-orientation effect of DSAEK grafts by observing the cross patterns and polarization power of human donor corneas using a polarizing device (Lumaxis(A (R))). Forty human donor corneas were placed in small petri-plates with epithelial side facing up. Polarizing power (arbitrary unit) and crosses were monitored and recorded by the software. The tissue was marked at 'Superior' position to ensure that the base and the polarizer are in alignment with each other after the cut. The anterior lamellar cut was performed using microkeratome. The lenticule was placed back in the same position as marked to mimic the alignment. The tissue was further rotated by 45A degrees ensuring that the base of the cornea and the polarizer were in alignment. The polarization power and 'crosses' were identified at each step. The average of forty corneas from pre-cut to post-45A degrees angular change showed statistically significant difference (p < 0.05) in terms of polarizing power. The cross-shaped pattern deformed and lost the sharpness towards 45A degrees angle. However, multiple variances in terms of 'cross-patterns' were observed throughout the study. Lumaxis(A (R)) was able to determine the worst quality tissue in terms of polarization (no black zone and crosses). Despite the quality of cross pattern which can be used as an additional objective parameter to evaluate the optical properties of the corneal tissue, this preliminary study needs to be further justified in terms of clinical relevance whether polarization changes with oriented or de-oriented grafts have any effects and consequences on the visual acuity.

Polarization of human donor corneas

Ferrari S.;Ponzin D.;
2016

Abstract

To investigate the de-orientation effect of DSAEK grafts by observing the cross patterns and polarization power of human donor corneas using a polarizing device (Lumaxis(A (R))). Forty human donor corneas were placed in small petri-plates with epithelial side facing up. Polarizing power (arbitrary unit) and crosses were monitored and recorded by the software. The tissue was marked at 'Superior' position to ensure that the base and the polarizer are in alignment with each other after the cut. The anterior lamellar cut was performed using microkeratome. The lenticule was placed back in the same position as marked to mimic the alignment. The tissue was further rotated by 45A degrees ensuring that the base of the cornea and the polarizer were in alignment. The polarization power and 'crosses' were identified at each step. The average of forty corneas from pre-cut to post-45A degrees angular change showed statistically significant difference (p < 0.05) in terms of polarizing power. The cross-shaped pattern deformed and lost the sharpness towards 45A degrees angle. However, multiple variances in terms of 'cross-patterns' were observed throughout the study. Lumaxis(A (R)) was able to determine the worst quality tissue in terms of polarization (no black zone and crosses). Despite the quality of cross pattern which can be used as an additional objective parameter to evaluate the optical properties of the corneal tissue, this preliminary study needs to be further justified in terms of clinical relevance whether polarization changes with oriented or de-oriented grafts have any effects and consequences on the visual acuity.
2016
Parekh, M.; Ruzza, A.; Ferrari, S.; Salvalaio, G.; Elbadawy, H.; Ponzin, D.; Lipari, E.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2619475
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact