The Jugular Venous Pulse (JVP) is considered a reliable parameter for the assessment of Central Venous Pressure (CVP). Here, the functionality of a cervical contact plethysmography system designed for non-invasive and operator-independent acquisition of the JVP signal, is shown. To validate the signal, it was recorded in supine and sitting positions, together with the reference Electrocardiography (ECG), on 26 healthy subjects. In the supine acquired signal, the characteristic JVP waves (a, c, v) and the negative deflections (x, y) are well recognizable. In the sitting recorded signal, the systolic peak b and the d incisura of the Common Carotid Artery (CCA) waveform are recognized. For each signal, we calculated the Fraction of the Cardiac Cycle (ccf) represented by the time intervals between the JVP peaks and the ECG peaks, in the form: ΔtaP, ΔtcR, ΔtxP, ΔtvT, Δtyv, Δtvx, and Δtxa. The same was done for the CCA waveform, in the form: ΔtbS, ΔtbT, Δtdb, ΔtdS, and ΔtdT. This system could mitigate risks and costs associated with central venous catheterization and its potential extends to applications in telemedicine, sports medicine, and space medicine.
Extraction of the jugular venous pulse and carotid profile using a cervical contact plethysmography system
Bruno SoggiaPrimo
;Anselmo Pagani
Secondo
;Antonino Proto;Rosa BrancaccioPenultimo
;Angelo TaibiUltimo
2024
Abstract
The Jugular Venous Pulse (JVP) is considered a reliable parameter for the assessment of Central Venous Pressure (CVP). Here, the functionality of a cervical contact plethysmography system designed for non-invasive and operator-independent acquisition of the JVP signal, is shown. To validate the signal, it was recorded in supine and sitting positions, together with the reference Electrocardiography (ECG), on 26 healthy subjects. In the supine acquired signal, the characteristic JVP waves (a, c, v) and the negative deflections (x, y) are well recognizable. In the sitting recorded signal, the systolic peak b and the d incisura of the Common Carotid Artery (CCA) waveform are recognized. For each signal, we calculated the Fraction of the Cardiac Cycle (ccf) represented by the time intervals between the JVP peaks and the ECG peaks, in the form: ΔtaP, ΔtcR, ΔtxP, ΔtvT, Δtyv, Δtvx, and Δtxa. The same was done for the CCA waveform, in the form: ΔtbS, ΔtbT, Δtdb, ΔtdS, and ΔtdT. This system could mitigate risks and costs associated with central venous catheterization and its potential extends to applications in telemedicine, sports medicine, and space medicine.File | Dimensione | Formato | |
---|---|---|---|
PAPER_2024_VEINS_Extraction of the Jugular Venous Pulse and carotid profile using a cervical contact plethysmography system.pdf
solo gestori archivio
Descrizione: Full text ahead of print
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
612.5 kB
Formato
Adobe PDF
|
612.5 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
vl-13-1-12664.pdf
accesso aperto
Descrizione: Full text editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
Creative commons
Dimensione
770.56 kB
Formato
Adobe PDF
|
770.56 kB | Adobe PDF | Visualizza/Apri |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.