Background: Currently, there is no evidence that MRI produces harmful effects on premature newborns, as well as short-term and long-term safety issues regarding radiofrequency fields and loud acoustic environment, while the examination that is being performed has not been clearly investigated. MRI of the brain conducted on preterm infants should be part of the diagnostic workup, when necessary. This article is intended to evaluate the short-term safety of MRI performed in preterm infants, when required, by analyzing all vital parameters available before, during, and after the MRI procedures. Methods: We conducted a systematic review of the literature on electronic medical databases (PubMed and ClinicalTrials.gov) following the Preferred Reported Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We included all preterm infants who underwent MRI whose clinical, hemodynamic, and respiratory parameters were reported. The quality of the included articles was assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool. Results: Six studies were included with a total of 311 preterm infants. No severe adverse event, such as death, occurred during MRI procedures. Vital signs remained stable in about two-thirds of all patients. Conclusions: Given the general clinical safety of MRI, we suggest it as a tool to be used in preterm infants in Neonatal Intensive Care Units, when necessary. We further suggest the development of standard protocols to guide the use of MRI in preterm infants to maximize the clinical safety of the procedure.
Magnetic Resonance Imaging in Preterm Infant: A Systematic Review on Clinical Procedure Safety
Falsaperla, Raffaele;Marino, Silvia;
2024
Abstract
Background: Currently, there is no evidence that MRI produces harmful effects on premature newborns, as well as short-term and long-term safety issues regarding radiofrequency fields and loud acoustic environment, while the examination that is being performed has not been clearly investigated. MRI of the brain conducted on preterm infants should be part of the diagnostic workup, when necessary. This article is intended to evaluate the short-term safety of MRI performed in preterm infants, when required, by analyzing all vital parameters available before, during, and after the MRI procedures. Methods: We conducted a systematic review of the literature on electronic medical databases (PubMed and ClinicalTrials.gov) following the Preferred Reported Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We included all preterm infants who underwent MRI whose clinical, hemodynamic, and respiratory parameters were reported. The quality of the included articles was assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool. Results: Six studies were included with a total of 311 preterm infants. No severe adverse event, such as death, occurred during MRI procedures. Vital signs remained stable in about two-thirds of all patients. Conclusions: Given the general clinical safety of MRI, we suggest it as a tool to be used in preterm infants in Neonatal Intensive Care Units, when necessary. We further suggest the development of standard protocols to guide the use of MRI in preterm infants to maximize the clinical safety of the procedure.I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.