Background: Anterior cervical corpectomy and plating has been recognized as a valuable approach for the surgical treatment of cervical spinal metastases. This study aimed to report the surgical, clinical and radiological outcomes of anterior carbon-PEEK instrumentations for cervical spinal metastases. Methods: Demographical, clinical, surgical and radiological data were collected from 2017 to 2020. The Neck Disability Index (NDI) questionnaire for neck pain, EORTC QLQ-C30 questionnaire for quality of life, Nurick scale for myelopathy and radiological parameters (segmental Cobb angle and cervical lordosis) were collected before surgery, at 6 weeks postoperatively and follow-up. Results: Seventeen patients met inclusion criteria. Mean age was 60.9 ± 7.6 years and mean follow-up was 12.9 ± 4.0 months. The NDI (55.4 ± 11.7 to 25.1 ± 5.4, p < 0.001) scores and the EORTC QLQ-C30 global health/QoL significantly improved postoperatively and at the last follow-up. The segmental Cobb angle (10.7◦ ± 5.6 to 3.1◦ ± 2.2, p < 0.001) and cervical lordosis (0.9◦ ± 6.7 to −6.2 ± 7.8, p = 0.002) significantly improved postoperatively. Only one minor com-plication (5.9%) was recorded. Conclusions: Carbon/PEEK implants represent a safe alternative to commonly used titanium ones and should be considered in cervical spinal metastases management due to their lower artifacts in postoperative imaging and radiation planning. Further larger comparative and cost-effectiveness studies are needed to confirm these results.

Anterior corpectomy and plating with carbon-peek instrumentation for cervical spinal metastases: clinical and radiological outcomes

Miscusi M.
Penultimo
;
2021

Abstract

Background: Anterior cervical corpectomy and plating has been recognized as a valuable approach for the surgical treatment of cervical spinal metastases. This study aimed to report the surgical, clinical and radiological outcomes of anterior carbon-PEEK instrumentations for cervical spinal metastases. Methods: Demographical, clinical, surgical and radiological data were collected from 2017 to 2020. The Neck Disability Index (NDI) questionnaire for neck pain, EORTC QLQ-C30 questionnaire for quality of life, Nurick scale for myelopathy and radiological parameters (segmental Cobb angle and cervical lordosis) were collected before surgery, at 6 weeks postoperatively and follow-up. Results: Seventeen patients met inclusion criteria. Mean age was 60.9 ± 7.6 years and mean follow-up was 12.9 ± 4.0 months. The NDI (55.4 ± 11.7 to 25.1 ± 5.4, p < 0.001) scores and the EORTC QLQ-C30 global health/QoL significantly improved postoperatively and at the last follow-up. The segmental Cobb angle (10.7◦ ± 5.6 to 3.1◦ ± 2.2, p < 0.001) and cervical lordosis (0.9◦ ± 6.7 to −6.2 ± 7.8, p = 0.002) significantly improved postoperatively. Only one minor com-plication (5.9%) was recorded. Conclusions: Carbon/PEEK implants represent a safe alternative to commonly used titanium ones and should be considered in cervical spinal metastases management due to their lower artifacts in postoperative imaging and radiation planning. Further larger comparative and cost-effectiveness studies are needed to confirm these results.
2021
Trungu, S.; Ricciardi, L.; Forcato, S.; Scollato, A.; Minniti, G.; Miscusi, M.; Raco, A.
File in questo prodotto:
File Dimensione Formato  
Trungu_Anterior_2021.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 4.64 MB
Formato Adobe PDF
4.64 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2530103
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact