Objective: To evaluate the accuracy of three different digital bracket positioning systems, comparing vertical, mesiodistal and buccolingual accuracy. Material and Methods: The same case was sent to Orapix, Insignia, and Orthocad systems and the brackets were bonded to the malocclusion models. Damon 3 MX brackets were used with all systems and the brackets were bonded to the models with the same bonding protocol and materials. The comparison of the position of each single bracket was made with digital photography, and ImageJ software was used to find the length in pixels and then convert it to hundredths of a mm for vertical, mesiodistal and buccolingual displacement, compared to the setup. Results: Insignia System reported the average higher vertical displacement (0.28 mm), compared with the other two appliances (0.22-0.23 mm), and showed the lowest average displacement for the mesiodistal and buccolingual positioning (0.14 and 0.07 mm, respectively). However, these slight bracket positioning variations between these bonding systems were not statistically different (p>0.05). Conclusion: The three systems analyzed were shown to be accurate in positioning the brackets, and none of them was statistically better.

Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems

Albertini, P
Primo
;
Cremonini, F
Penultimo
;
Palone, M
Ultimo
2021

Abstract

Objective: To evaluate the accuracy of three different digital bracket positioning systems, comparing vertical, mesiodistal and buccolingual accuracy. Material and Methods: The same case was sent to Orapix, Insignia, and Orthocad systems and the brackets were bonded to the malocclusion models. Damon 3 MX brackets were used with all systems and the brackets were bonded to the models with the same bonding protocol and materials. The comparison of the position of each single bracket was made with digital photography, and ImageJ software was used to find the length in pixels and then convert it to hundredths of a mm for vertical, mesiodistal and buccolingual displacement, compared to the setup. Results: Insignia System reported the average higher vertical displacement (0.28 mm), compared with the other two appliances (0.22-0.23 mm), and showed the lowest average displacement for the mesiodistal and buccolingual positioning (0.14 and 0.07 mm, respectively). However, these slight bracket positioning variations between these bonding systems were not statistically different (p>0.05). Conclusion: The three systems analyzed were shown to be accurate in positioning the brackets, and none of them was statistically better.
2021
Albertini, P; Tremaroli, M; Cremonini, F; Palone, M
File in questo prodotto:
File Dimensione Formato  
Albertini Pesquisa 2021. Comparative of bracket position accuracy with different CAD-CAM indirect bonding system.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 1.7 MB
Formato Adobe PDF
1.7 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2500595
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact