Background: To compare anatomical, functional outcomes and complications of high-speed 25-gauge (G) pars plana vitrectomy (PPV) versus 20-G PPV for the management of primary inferior rhegmatogenous retinal detachment (RRD) associated to inferior breaks/holes. Methods: Eighty-five eyes from 85 patients with a minimum follow-up of 3 months were retrospectively evaluated. Forty-one patients underwent 25-G and 44 patients underwent 20-G PPV. All patients underwent PPV with fluid-air exchange, sulfur hexafluoride (SF6) 20 % gas tamponade and laser or cryo retinopexy. Results: The mean follow-up interval was 6.51(±2.32) and 6.63 (±2.58) months in the 25-G and 20-G groups respectively. Single-operation success rate was 92.7 % for the 25-G group and 81.8 % for the 20-G group (P = 0.24). Post-operative hypotony was observed in no case. Redetachment occurred in 3 eyes operated on with 25-G and in 8 eyes operated on with 20-G system. All retinas were attached at final follow-up. Logarithm of the minimum angle of resolution visual acuity significantly improved from 0.69 ± 0.76 to 0.33 ± 0.37 in the 25-G and from 0.47 ± 0.59 to 0.21 ± 0.28 in the 20-G group (P = 0.0007 and P < 0.0001 respectively). Conclusions: High-speed PPV and SF6 gas tamponade using either 25-G or 20-G PPV system, yields similar single operation anatomical success rates for the repair of uncomplicated, primary inferior RRDs associated to inferior breaks.

Pars plana vitrectomy for the repair of primary inferior rhegmatogenous retinal detachment associated to inferior breaks. A comparison 25-gauge versus 20-gauge system

Mura M
Ultimo
2013

Abstract

Background: To compare anatomical, functional outcomes and complications of high-speed 25-gauge (G) pars plana vitrectomy (PPV) versus 20-G PPV for the management of primary inferior rhegmatogenous retinal detachment (RRD) associated to inferior breaks/holes. Methods: Eighty-five eyes from 85 patients with a minimum follow-up of 3 months were retrospectively evaluated. Forty-one patients underwent 25-G and 44 patients underwent 20-G PPV. All patients underwent PPV with fluid-air exchange, sulfur hexafluoride (SF6) 20 % gas tamponade and laser or cryo retinopexy. Results: The mean follow-up interval was 6.51(±2.32) and 6.63 (±2.58) months in the 25-G and 20-G groups respectively. Single-operation success rate was 92.7 % for the 25-G group and 81.8 % for the 20-G group (P = 0.24). Post-operative hypotony was observed in no case. Redetachment occurred in 3 eyes operated on with 25-G and in 8 eyes operated on with 20-G system. All retinas were attached at final follow-up. Logarithm of the minimum angle of resolution visual acuity significantly improved from 0.69 ± 0.76 to 0.33 ± 0.37 in the 25-G and from 0.47 ± 0.59 to 0.21 ± 0.28 in the 20-G group (P = 0.0007 and P < 0.0001 respectively). Conclusions: High-speed PPV and SF6 gas tamponade using either 25-G or 20-G PPV system, yields similar single operation anatomical success rates for the repair of uncomplicated, primary inferior RRDs associated to inferior breaks.
2013
Dell’Omo, R; Barca, F; Tan, Hs; Bijl, Hm; Oberstein, Sy; Mura, M
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2482033
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 26
social impact