Purpose To describe the use of a novel intra-ocular side-scanning probe enabling the acquisition of spectral-domain optical coherence tomography (SD-OCT) images during surgery in a series of patients with complex forms of retinal detachment. Methods A 23-gauge, side-scanning SD-OCT probe (C7 System; LightLab Imaging, Inc/St Jude Medical, St. Paul, MN, USA) in a 20-gauge catheter, was used to acquire the intra-operative OCT images in seven patients with vitreoretinal diseases. Twenty-five gauge pars plana vitrectomy (PPV) was performed in every patient in a standard fashion. After enlarging the temporal sclerotomy to a 20-gauge port, all the patients were scanned with intra-ocular side-scanning SD-OCT, during different steps of the surgery based on surgeon needs. Scans were recorded real time and directly evaluated on a screen during surgery. Optical coherence tomography (OCT) scans were judged beneficial when they would recognize structures otherwise not seen on biomicroscopy. Results The intra-ocular SD-OCT has been helpful in acquiring extra information during vitreoretinal surgery such as the detection of the presence of otherwise invisible membranes (epiretinal membrane, subretinal membrane), the location of small tears and the identification of the retinal plane under suboptimal conditions for visualization. Conclusion The use of an intra-ocular SD-OCT can expand upon visual cues during surgery, helping in the decision-making process and allowing additional deliberate surgical manoeuvres aimed at improving surgical outcomes.

Use of a new intraocular spectral domain optical coherence tomography in vitreoretinal surgery

Mura M
Primo
;
2016

Abstract

Purpose To describe the use of a novel intra-ocular side-scanning probe enabling the acquisition of spectral-domain optical coherence tomography (SD-OCT) images during surgery in a series of patients with complex forms of retinal detachment. Methods A 23-gauge, side-scanning SD-OCT probe (C7 System; LightLab Imaging, Inc/St Jude Medical, St. Paul, MN, USA) in a 20-gauge catheter, was used to acquire the intra-operative OCT images in seven patients with vitreoretinal diseases. Twenty-five gauge pars plana vitrectomy (PPV) was performed in every patient in a standard fashion. After enlarging the temporal sclerotomy to a 20-gauge port, all the patients were scanned with intra-ocular side-scanning SD-OCT, during different steps of the surgery based on surgeon needs. Scans were recorded real time and directly evaluated on a screen during surgery. Optical coherence tomography (OCT) scans were judged beneficial when they would recognize structures otherwise not seen on biomicroscopy. Results The intra-ocular SD-OCT has been helpful in acquiring extra information during vitreoretinal surgery such as the detection of the presence of otherwise invisible membranes (epiretinal membrane, subretinal membrane), the location of small tears and the identification of the retinal plane under suboptimal conditions for visualization. Conclusion The use of an intra-ocular SD-OCT can expand upon visual cues during surgery, helping in the decision-making process and allowing additional deliberate surgical manoeuvres aimed at improving surgical outcomes.
2016
Mura, M; Iannetta, D; Barca, F; Nasini, F; Engelbrecht, L; de Smet, M; Verbraak, ; F,
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2481949
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact