Objective: To analyze and compare the stiffness of different lingual appliances with different archwires. Material and Methods: The three-point bending test was used to analyze the stiffness of the lingual archwires for the different lingual systems: eBrace, Harmony, Incognito, and STb. The deflection load curve of each archwire was obtained to evaluate how the section, the material and the manufacturer affect the elasticity and stiffness characteristics of the wires. The comparison of the stiffness between different systems was carried out through a factor variance analysis with three factors (manufacturer, cross-section, and material), followed by the post-hoc Tuckey test. Results: An increase in the system's rigidity was reported as the wire section increases, regardless of the manufacturer. The stainless steel archwires have ever higher stiffness values than NiTi and TMA. The STb wires of CuNiTi material, by virtue of the characteristics of the thermal wires, have flatter and lower load-deflection curves than the NiTi wires of other manufacturers. Conclusion: Archwires section and material showed a significant influence on the stiffness of the lingual systems. Archwires of the same section and material but different manufacturers show different load-deflection curves of stiffness.

Comparative analysis of stiffness of lingual appliances: An in vitro study

Albertini P.
Primo
;
Cremonini F.
Secondo
;
Palone M.
Ultimo
2021

Abstract

Objective: To analyze and compare the stiffness of different lingual appliances with different archwires. Material and Methods: The three-point bending test was used to analyze the stiffness of the lingual archwires for the different lingual systems: eBrace, Harmony, Incognito, and STb. The deflection load curve of each archwire was obtained to evaluate how the section, the material and the manufacturer affect the elasticity and stiffness characteristics of the wires. The comparison of the stiffness between different systems was carried out through a factor variance analysis with three factors (manufacturer, cross-section, and material), followed by the post-hoc Tuckey test. Results: An increase in the system's rigidity was reported as the wire section increases, regardless of the manufacturer. The stainless steel archwires have ever higher stiffness values than NiTi and TMA. The STb wires of CuNiTi material, by virtue of the characteristics of the thermal wires, have flatter and lower load-deflection curves than the NiTi wires of other manufacturers. Conclusion: Archwires section and material showed a significant influence on the stiffness of the lingual systems. Archwires of the same section and material but different manufacturers show different load-deflection curves of stiffness.
2021
Albertini, P.; Cremonini, F.; Palone, M.
File in questo prodotto:
File Dimensione Formato  
Albertini 2021. Pesquisa. Comparative Analysis of Stiffness of Lingual Appliances An in Vitro Study.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 1.15 MB
Formato Adobe PDF
1.15 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2479139
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 2
social impact