The aim of the present investigation was to evaluate the efficacy of an antibacterial coating of implantabutment prosthetic junctions by real time measurement of Volatile Organic Compounds (VOCs). A total of 20 patients and 40 internal prosthetic junction implants were evaluated in the present investigation: 20 fixtures with antibacterial internal coating (Test) and 20 without treatment (Control). The VOCs measurements were evaluated at the baseline (T0) after the cover unit unscrewing, after 7 days (T1) and at 14 days (T2). No significant difference were detected at T0 (baseline), as Test and Control groups showed a VOCs max peak mean respectively of 2.15±0.71 and 2.21±0.69 (p > 0.05). At T1 and T2 as significant difference between the Test and Control Groups was detected (p < 0.01). At T2 the Test max peak was 2.29 ± 0.73 and the Control was 3.65 ± 0.91 (p < 0.01). The antibacterial internal coating demonstrated the capacity to prevent microbial VOCS activity at the level of the implant internal chamber and could be useful for long-term peri-implant tissue health.

Evaluation of a new antibacterial coating of the internal chamber of an implant via real time measurement of Volatile Organic Compounds (VOCs)

Carinci F.;
2021

Abstract

The aim of the present investigation was to evaluate the efficacy of an antibacterial coating of implantabutment prosthetic junctions by real time measurement of Volatile Organic Compounds (VOCs). A total of 20 patients and 40 internal prosthetic junction implants were evaluated in the present investigation: 20 fixtures with antibacterial internal coating (Test) and 20 without treatment (Control). The VOCs measurements were evaluated at the baseline (T0) after the cover unit unscrewing, after 7 days (T1) and at 14 days (T2). No significant difference were detected at T0 (baseline), as Test and Control groups showed a VOCs max peak mean respectively of 2.15±0.71 and 2.21±0.69 (p > 0.05). At T1 and T2 as significant difference between the Test and Control Groups was detected (p < 0.01). At T2 the Test max peak was 2.29 ± 0.73 and the Control was 3.65 ± 0.91 (p < 0.01). The antibacterial internal coating demonstrated the capacity to prevent microbial VOCS activity at the level of the implant internal chamber and could be useful for long-term peri-implant tissue health.
2021
Scarano, A.; De Oliveira, P. S.; Leo, L.; Festa, F.; Carinci, F.; Lorusso, F.
File in questo prodotto:
File Dimensione Formato  
Elite879.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 2.1 MB
Formato Adobe PDF
2.1 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2477384
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact