Radioimmunotherapy (RIT) is a safe and active treatment available for non-Hodgkin lymphomas (NHLs). In particular, two monoclonal antibodies raised against CD20, that is Zevalin (90Y-ibritumomab-tiuxetan) and Bexxar (131I-tositumomab) received FDA approval for the treatment of relapsing/refractory indolent or transformed NHLs. RIT is likely the most effective and least toxic anticancer agent in NHLs. However, its use in the clinical setting is still debated and, in case of relapse after optimized rituximab-containing regimens, the efficacy of RIT at standard dosage is suboptimal. Thus, clinical trials were based on the hypothesis that the inclusion of RIT in myeloablative conditioning would allow to obtain improved efficacy and toxicity profiles when compared to myeloablative total-body irradiation and/or high-dose chemotherapy regimens. Standard-activity RIT has a safe toxicity profile, and the utility of pretherapeutic dosimetry in this setting can be disputed. In contrast, dose-escalation clinical protocols require the assessment of radiopharmaceutical biodistribution and dosimetry before the therapeutic injection, as dose constrains for critical organs may be exceeded when RIT is administered at high activities. The aim of the present study was to review and discuss the internal dosimetry protocols that were adopted for non-standard RIT administration in the myeloablative setting before hematopoietic stem cell transplantation in patients with NHLs.

Dosimetric Approaches for Radioimmunotherapy of Non-Hodgkin Lymphoma in Myeloablative Setting

Sarnelli A.
Secondo
;
Paganelli G.
Ultimo
2022

Abstract

Radioimmunotherapy (RIT) is a safe and active treatment available for non-Hodgkin lymphomas (NHLs). In particular, two monoclonal antibodies raised against CD20, that is Zevalin (90Y-ibritumomab-tiuxetan) and Bexxar (131I-tositumomab) received FDA approval for the treatment of relapsing/refractory indolent or transformed NHLs. RIT is likely the most effective and least toxic anticancer agent in NHLs. However, its use in the clinical setting is still debated and, in case of relapse after optimized rituximab-containing regimens, the efficacy of RIT at standard dosage is suboptimal. Thus, clinical trials were based on the hypothesis that the inclusion of RIT in myeloablative conditioning would allow to obtain improved efficacy and toxicity profiles when compared to myeloablative total-body irradiation and/or high-dose chemotherapy regimens. Standard-activity RIT has a safe toxicity profile, and the utility of pretherapeutic dosimetry in this setting can be disputed. In contrast, dose-escalation clinical protocols require the assessment of radiopharmaceutical biodistribution and dosimetry before the therapeutic injection, as dose constrains for critical organs may be exceeded when RIT is administered at high activities. The aim of the present study was to review and discuss the internal dosimetry protocols that were adopted for non-standard RIT administration in the myeloablative setting before hematopoietic stem cell transplantation in patients with NHLs.
2022
Cicone, F.; Sarnelli, A.; Guidi, C.; Belli, M. L.; Ferrari, M. E.; Wahl, R.; Cremonesi, M.; Paganelli, G.
File in questo prodotto:
File Dimensione Formato  
review_paganelli_Final_Draft.pdf

accesso aperto

Descrizione: Pre-print
Tipologia: Pre-print
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 5.59 MB
Formato Adobe PDF
5.59 MB Adobe PDF Visualizza/Apri
1-s2.0-S000129982100088X-main.pdf

solo gestori archivio

Descrizione: Full text ahead of print
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.66 MB
Formato Adobe PDF
1.66 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
1-s2.0-S000129982100088X-main.pdf

solo gestori archivio

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.7 MB
Formato Adobe PDF
1.7 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2472692
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact