The study below presents the main results of numerical analyzes, performed to assess the seismic response of an existing building, with brick masonry, type 77/5. This building is part of the group of 4-5 residential buildings, built in the years 1975-1990, considered as a “TYPE”, each of which was used many times for identical buildings. This project is the result of a collective work of the Design Institute, approved by the Ministry of Construction of that time, and of course, manifests the time limitations and shortcomings. While these 5-story buildings cover a significant percentage of residential buildings, the fundamental question is: “Are these buildings safe under seismic action, while so many families are accommodated on them?” This question stems from the following limitation: - The 77/5 plan derives from regular forms, based on the recommendations of Eurocode 8 [4.2.3.2], p.48, and KTP.N.2-89 (Technical Design Conditions), published by the Academy of Sciences of Albania. - The technical literature provides recommendations and restrictions for masonry buildings with a height of not more than 3 floors. When they exceed this height, they are not included in these recommendations.

Analysis of 5 Floors Brick Masonry Building Type 77/5

Nikolla Vesho
Membro del Collaboration Group
;
2021

Abstract

The study below presents the main results of numerical analyzes, performed to assess the seismic response of an existing building, with brick masonry, type 77/5. This building is part of the group of 4-5 residential buildings, built in the years 1975-1990, considered as a “TYPE”, each of which was used many times for identical buildings. This project is the result of a collective work of the Design Institute, approved by the Ministry of Construction of that time, and of course, manifests the time limitations and shortcomings. While these 5-story buildings cover a significant percentage of residential buildings, the fundamental question is: “Are these buildings safe under seismic action, while so many families are accommodated on them?” This question stems from the following limitation: - The 77/5 plan derives from regular forms, based on the recommendations of Eurocode 8 [4.2.3.2], p.48, and KTP.N.2-89 (Technical Design Conditions), published by the Academy of Sciences of Albania. - The technical literature provides recommendations and restrictions for masonry buildings with a height of not more than 3 floors. When they exceed this height, they are not included in these recommendations.
2021
Koka, Petraq; Vesho, Nikolla; Shehu, Fabion
File in questo prodotto:
File Dimensione Formato  
2517-Article Text-9760-1-10-20210722.pdf

accesso aperto

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 622.86 kB
Formato Adobe PDF
622.86 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2470611
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact