Stent under-expansion represents a negative prognostic factor, because of the risk to develop intrastent restenosis and stent thrombosis. It is often due to excessive calcium burden at the target lesion level. The list of devices available for the treatment of stent under-expansion includes super high-pressure non-com- pliant (NC) balloons, excimer laser and intravascular lithotripsy. NC OPNTM balloons (SIS Medical AG, Winterthur, Switzerland) reach much higher pressures than those of standard NC balloons (up to 35 atm), so they are able to overcome the resistance given by the calcific plaque. The excimer laser catheter instead generates ultraviolet light pulses with low penetration power. This one fragments the atherosclerotic material surrounding the implanted stent. This technology has proven to be extremely effective, however it requires specific operator experience to reduce the risk of serious complica- tions. Intravascular lithotripsy is the most recent method, and it has shown very promising results so far. The Shockwave Medical device (S-IVL; Shockwave Medical Inc, Santa Clara, CA, USA) emits sound waves that act selectively on the calcific component, breaking it up and making the vessel more compliant.

Strategie per la gestione della sotto-espansione dello stent [Management of stent under-expansion]

Erriquez Andrea
Primo
;
Pavasini Rita
Secondo
;
Campo Gianluca
Ultimo
2020

Abstract

Stent under-expansion represents a negative prognostic factor, because of the risk to develop intrastent restenosis and stent thrombosis. It is often due to excessive calcium burden at the target lesion level. The list of devices available for the treatment of stent under-expansion includes super high-pressure non-com- pliant (NC) balloons, excimer laser and intravascular lithotripsy. NC OPNTM balloons (SIS Medical AG, Winterthur, Switzerland) reach much higher pressures than those of standard NC balloons (up to 35 atm), so they are able to overcome the resistance given by the calcific plaque. The excimer laser catheter instead generates ultraviolet light pulses with low penetration power. This one fragments the atherosclerotic material surrounding the implanted stent. This technology has proven to be extremely effective, however it requires specific operator experience to reduce the risk of serious complica- tions. Intravascular lithotripsy is the most recent method, and it has shown very promising results so far. The Shockwave Medical device (S-IVL; Shockwave Medical Inc, Santa Clara, CA, USA) emits sound waves that act selectively on the calcific component, breaking it up and making the vessel more compliant.
2020
Erriquez, Andrea; Pavasini, Rita; Campo, Gianluca
File in questo prodotto:
File Dimensione Formato  
04 Erriquez (21-26).pdf

solo gestori archivio

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 989.06 kB
Formato Adobe PDF
989.06 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2436673
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact