MariX is a research infrastructure conceived for multi-disciplinary studies, based on a cutting-edge system of combined electron accelerators at the forefront of the world-wide scenario of X-ray sources. The generation of X-rays over a large photon energy range will be enabled by two unique X-ray sources: a Free Electron Laser and an inverse Compton source, called BriXS (Bright compact X-ray Source). The X-ray beam provided by BriXS is expected to have an average energy tunable in the range 20-180 keV and intensities between 1011 and 1013 photon/s within a relative bandwidth ΔE/E=1-10%. These characteristics, together with a very small source size (~20 μm) and a good transverse coherence, will enable a wide range of applications in the bio-medical field. An additional unique feature of BriXS will be the possibility to make a quick switch of the X-ray energy between two values for dual-energy and K-edge subtraction imaging. In this paper, the expected characteristics of BriXS will be presented, with a particular focus on the features of interest to its possible medical applications.
BriXS, a new X-ray inverse Compton source for medical applications
Cardarelli, P;Gambaccini, M;Paternò, G;Taibi, APenultimo
;
2020
Abstract
MariX is a research infrastructure conceived for multi-disciplinary studies, based on a cutting-edge system of combined electron accelerators at the forefront of the world-wide scenario of X-ray sources. The generation of X-rays over a large photon energy range will be enabled by two unique X-ray sources: a Free Electron Laser and an inverse Compton source, called BriXS (Bright compact X-ray Source). The X-ray beam provided by BriXS is expected to have an average energy tunable in the range 20-180 keV and intensities between 1011 and 1013 photon/s within a relative bandwidth ΔE/E=1-10%. These characteristics, together with a very small source size (~20 μm) and a good transverse coherence, will enable a wide range of applications in the bio-medical field. An additional unique feature of BriXS will be the possibility to make a quick switch of the X-ray energy between two values for dual-energy and K-edge subtraction imaging. In this paper, the expected characteristics of BriXS will be presented, with a particular focus on the features of interest to its possible medical applications.File | Dimensione | Formato | |
---|---|---|---|
2020.TAIBI.BriXS.pdf
solo gestori archivio
Descrizione: versione editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
2.19 MB
Formato
Adobe PDF
|
2.19 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.