Background: Open abdomen (OA) is a surgical option that can be used in patients with severe peritonitis. Few evidences exist to recommend the use of intraperitoneal fluid instillation associated with OA in managing septic abdomen. Materials and methods: A prospective analysis of adult patients enrolled in the International Register of Open Abdomen (trial registration: NCT02382770) was performed. Results: A total of 387 patients were enrolled in two groups: 84 with peritoneal fluid instillation (FI) and 303 without (NFI). The groups were homogeneous for baseline characteristics. Overall complications were 92.9% in FI and 86.3% in NFI (p = 0.106). Complications during OA were 72.6% in FI and 59.9% in NFI (p = 0.034). Complications after definitive closure were 70.8% in FI and 61.1% in NFI (p = 0.133). Entero-atmospheric fistula was 13.1% in FI and 12% in NFI (p = 0.828). Fascial closure was 78.6% in FI and 63.7% in NFI (p = 0.02). Analysis of FI in negative pressure wound therapy (NPWT) showed: Overall morbidity in NPWT was 94% and in non-NPWT 91.2% (p = 0.622) and morbidity during OA was 68% and 79.4% (p = 0.25), respectively. Definitive fascial closure in NPWT was 87.8% and 96.8% in non-NPWT (p = 0.173). Overall mortality was 40% in NPWT and 29.4% in non-NPWT (p = 0.32) and morality during OA period was 18% and 8.8% (p = 0.238), respectively. Conclusion: We found intraperitoneal fluid instillation during open abdomen in peritonitic patients to increase the complication rate during the open abdomen period, with no impact on mortality, entero-atmospheric fistula rate and opening time. Fascial closure rate is increased by instillation. Fluid instillation is feasible even when associated with nonnegative pressure temporary abdominal closure techniques.

Open Abdomen and Fluid Instillation in the Septic Abdomen: Results from the IROA Study

Gubbiotti F.;Montori G.
Membro del Collaboration Group
;
Salvetti F.
Membro del Collaboration Group
;
Zese M.
Membro del Collaboration Group
;
Occhionorelli S.
Membro del Collaboration Group
;
Trotta F.
Membro del Collaboration Group
;
Porta M.
Membro del Collaboration Group
;
2020

Abstract

Background: Open abdomen (OA) is a surgical option that can be used in patients with severe peritonitis. Few evidences exist to recommend the use of intraperitoneal fluid instillation associated with OA in managing septic abdomen. Materials and methods: A prospective analysis of adult patients enrolled in the International Register of Open Abdomen (trial registration: NCT02382770) was performed. Results: A total of 387 patients were enrolled in two groups: 84 with peritoneal fluid instillation (FI) and 303 without (NFI). The groups were homogeneous for baseline characteristics. Overall complications were 92.9% in FI and 86.3% in NFI (p = 0.106). Complications during OA were 72.6% in FI and 59.9% in NFI (p = 0.034). Complications after definitive closure were 70.8% in FI and 61.1% in NFI (p = 0.133). Entero-atmospheric fistula was 13.1% in FI and 12% in NFI (p = 0.828). Fascial closure was 78.6% in FI and 63.7% in NFI (p = 0.02). Analysis of FI in negative pressure wound therapy (NPWT) showed: Overall morbidity in NPWT was 94% and in non-NPWT 91.2% (p = 0.622) and morbidity during OA was 68% and 79.4% (p = 0.25), respectively. Definitive fascial closure in NPWT was 87.8% and 96.8% in non-NPWT (p = 0.173). Overall mortality was 40% in NPWT and 29.4% in non-NPWT (p = 0.32) and morality during OA period was 18% and 8.8% (p = 0.238), respectively. Conclusion: We found intraperitoneal fluid instillation during open abdomen in peritonitic patients to increase the complication rate during the open abdomen period, with no impact on mortality, entero-atmospheric fistula rate and opening time. Fascial closure rate is increased by instillation. Fluid instillation is feasible even when associated with nonnegative pressure temporary abdominal closure techniques.
2020
Coccolini, F.; Gubbiotti, F.; Ceresoli, M.; Tartaglia, D.; Fugazzola, P.; Ansaloni, L.; Sartelli, M.; Kluger, Y.; Kirkpatrick, A.; Amico, F.; Catena, ...espandi
File in questo prodotto:
File Dimensione Formato  
Open-Abdomen-and-Fluid-Instillation-in-the-Septic-Abdomen-Results-from-the-IROA-Study2020World-Journal-of-Surgery.pdf

accesso aperto

Descrizione: versione ahead of print
Tipologia: Altro materiale allegato
Licenza: Creative commons
Dimensione 534.84 kB
Formato Adobe PDF
534.84 kB Adobe PDF Visualizza/Apri
Coccolini2020_Article_OpenAbdomenAndFluidInstillatio.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 524.17 kB
Formato Adobe PDF
524.17 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2422210
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact