van ’t Hoff plots (logarithm of the retention factor, ln k, vs. the reciprocal of absolute temperature, 1/T) are commonly used in chromatographic studies to characterize the retention mechanisms based on the determined enthalpy (ΔH∘) and entropy (ΔS∘) change of analyte adsorption. In reversed phase liquid chromatography, the thermodynamic parameters could help to understand the retention mechanism. In chiral chromatography, however, the conclusions drawn based on van ’t Hoff plots can be deceptive because several different types of adsorption sites are present on the surface of stationary phase. The influence of heterogeneity, however, cannot be studied experimentally. In this study, we employed two reversed phase columns with different retention mechanisms to show that by serially coupling the columns, the obtained thermodynamic parameters are not related to the results obtained on the respective individual columns. Furthermore, our results show that the experimental conditions – such as flow-rate or choice of instrument – will strongly influence the calculated enthalpy and entropy values.

The correctness of van ’t Hoff plots in chiral and achiral chromatography

Martina Catani
Penultimo
;
2020

Abstract

van ’t Hoff plots (logarithm of the retention factor, ln k, vs. the reciprocal of absolute temperature, 1/T) are commonly used in chromatographic studies to characterize the retention mechanisms based on the determined enthalpy (ΔH∘) and entropy (ΔS∘) change of analyte adsorption. In reversed phase liquid chromatography, the thermodynamic parameters could help to understand the retention mechanism. In chiral chromatography, however, the conclusions drawn based on van ’t Hoff plots can be deceptive because several different types of adsorption sites are present on the surface of stationary phase. The influence of heterogeneity, however, cannot be studied experimentally. In this study, we employed two reversed phase columns with different retention mechanisms to show that by serially coupling the columns, the obtained thermodynamic parameters are not related to the results obtained on the respective individual columns. Furthermore, our results show that the experimental conditions – such as flow-rate or choice of instrument – will strongly influence the calculated enthalpy and entropy values.
2020
Sepsey, Annamária; Horváth, Éva; Catani, Martina; Felinger, Attila
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0021967319310027-main.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 1.52 MB
Formato Adobe PDF
1.52 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2414969
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 27
social impact