The ELI-NP facility will provide a monochromatic, high brilliance γ beam with tunable energy up to 19.5 MeV. The time structure of the beam consists of 32 pulses of 105 photons separated by 16 ns and delivered at repetition rate of 100 Hz. In order to match such unprecedented beam specifications and to measure its energy spectrum, intensity and space profile, a characterization system has been developed. This paper will focus on the working principle, the expected performances and the results of tests carried out on a low-Z sampling calorimeter, made of silicon detectors and polyethylene absorbers, which will measure the average beam energy and its intensity. The results of tests performed with an infrared pulsed laser have shown the capability of the detector to cope with the time structure of ELI-NP beam. Further tests carried out at the LABEC facility in Firenze have shown the excellent linearity of the silicon detectors in the energy range relevant to ELI-NP beam.

A γ calorimeter for the monitoring of the ELI-NP beam

Cardarelli, P.;Di Domenico, G.;Gambaccini, M.;Marziani, M.;Paternò, G.;
2019

Abstract

The ELI-NP facility will provide a monochromatic, high brilliance γ beam with tunable energy up to 19.5 MeV. The time structure of the beam consists of 32 pulses of 105 photons separated by 16 ns and delivered at repetition rate of 100 Hz. In order to match such unprecedented beam specifications and to measure its energy spectrum, intensity and space profile, a characterization system has been developed. This paper will focus on the working principle, the expected performances and the results of tests carried out on a low-Z sampling calorimeter, made of silicon detectors and polyethylene absorbers, which will measure the average beam energy and its intensity. The results of tests performed with an infrared pulsed laser have shown the capability of the detector to cope with the time structure of ELI-NP beam. Further tests carried out at the LABEC facility in Firenze have shown the excellent linearity of the silicon detectors in the energy range relevant to ELI-NP beam.
2019
Veltri, M.; Adriani, O.; Albergo, S.; Andreotti, M.; Borgheresi, R.; Cappello, G.; Cardarelli, P.; Ciaranfi, R.; Consoli, E.; Di Domenico, G.; Evangelisti, F.; Gambaccini, M.; Graziani, G.; Lenzi, M.; Maletta, F.; Marziani, M.; Passaleva, G.; Paternò, G.; Serban, A.; Squerzanti, S.; Starodubtsev, O.; Tricomi, A.; Variola, A.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0168900218313159-main (1).pdf

solo gestori archivio

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 535.13 kB
Formato Adobe PDF
535.13 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2401001
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact