Objective: To test the efficacy of a recently introduced ultrasonic scanning plane (three vessel and trachea view -3VTV- plus color flow mapping -3VTVC) on a low-risk population for detection of congenital heart disease (CHD). Patients and setting: Antenatal clinic dealing with local low-risk population. All antenatal patients having a second trimester scan in a 1 year period. All patients had a 3VT plus 3VTC views added to routine four chamber view. Postnatal examinations were performed according to standard hospital protocol. Results: 2847 patients were examined. The plane was achievable in all 23 fetuses with CHD detected, three false negative (aortic coarctation) and two false positive. Sensitivity of the examination was 88.5%, as high as more sophisticated and difficult targeted cardiac scanning. The extra time necessary to perform the test was minimal. Conclusion: 3VTV and 3VTCV were satisfactory used as imaging planes in a busy antenatal clinic in a low-risk population. They could be easily added to the four chamber view as routine screening for CHD and increase the detection rate to 90%. Copyright © by Walter de Gruyter.

Four chamber view plus three-vessel and trachea view for a complete evaluation of the fetal heart during the second trimester

Greco, Pantaleo
2006

Abstract

Objective: To test the efficacy of a recently introduced ultrasonic scanning plane (three vessel and trachea view -3VTV- plus color flow mapping -3VTVC) on a low-risk population for detection of congenital heart disease (CHD). Patients and setting: Antenatal clinic dealing with local low-risk population. All antenatal patients having a second trimester scan in a 1 year period. All patients had a 3VT plus 3VTC views added to routine four chamber view. Postnatal examinations were performed according to standard hospital protocol. Results: 2847 patients were examined. The plane was achievable in all 23 fetuses with CHD detected, three false negative (aortic coarctation) and two false positive. Sensitivity of the examination was 88.5%, as high as more sophisticated and difficult targeted cardiac scanning. The extra time necessary to perform the test was minimal. Conclusion: 3VTV and 3VTCV were satisfactory used as imaging planes in a busy antenatal clinic in a low-risk population. They could be easily added to the four chamber view as routine screening for CHD and increase the detection rate to 90%. Copyright © by Walter de Gruyter.
2006
Del Bianco, Antongiulio; Russo, Salvatore; Lacerenza, Nicola; Rinaldi, Matteo; Rinaldi, Giuseppe; Nappi, Luigi; Greco, Pantaleo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2387774
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 46
social impact