Background Randomized clinical trials on bioresorbable scaffolds (BRS) enrolled patients with simple coronary lesions. The present study was sought to give preliminary findings about safety of BRS implantation in overlap in long coronary lesions. Methods From June 2012 to January 2015, we prospectively collected data from 162 consecutive patients receiving overlapping BRS implantation in the 16 participating institutions. We applied a propensity-score to match BRS-treated patients with 162 patients receiving second generation drug eluting stents (DES) in overlap. The primary endpoint was a device-oriented endpoint (DOCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization. Results DOCE rate did not significantly differ between the two groups (5.6% in BRS group vs. 7.4% in DES group, HR 0.79, 95%CI 0.37-3.55, p = 0.6). Also stent/scaffold thrombosis did not differ between groups (1.2% in BRS group vs. 1.9% in DES group, p = 0.6). Occurrence of procedural-related myocardial injury was significantly higher in the BRS group (25% vs. 12%, p = 0.001), although it was not related to DOCE (HR 1.1, 95%CI 0.97-1.2, p = 0.2). Imaging techniques and enhanced stent visualization systems were significantly more employed in the BRS group (p = 0.0001 for both). Procedure length, fluoroscopy time and contrast dye amount were significantly higher in the BRS group (p = 0.001, p = 0.001 and p = 0.01, respectively). Conclusions Overlapping BRS utilization in long coronary lesions showed a comparable DOCE rate at 1 year if compared to second generation DES. Further and larger studies are on demand to confirm our findings.
Bioresorbable Scaffold vs. Second Generation Drug Eluting Stent in Long Coronary Lesions requiring Overlap: A Propensity-Matched Comparison (the UNDERDOGS study)
BISCAGLIA, Simone
Primo
;PENZO, Carlo;CAMPO, Gianluca CalogeroUltimo
2016
Abstract
Background Randomized clinical trials on bioresorbable scaffolds (BRS) enrolled patients with simple coronary lesions. The present study was sought to give preliminary findings about safety of BRS implantation in overlap in long coronary lesions. Methods From June 2012 to January 2015, we prospectively collected data from 162 consecutive patients receiving overlapping BRS implantation in the 16 participating institutions. We applied a propensity-score to match BRS-treated patients with 162 patients receiving second generation drug eluting stents (DES) in overlap. The primary endpoint was a device-oriented endpoint (DOCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization. Results DOCE rate did not significantly differ between the two groups (5.6% in BRS group vs. 7.4% in DES group, HR 0.79, 95%CI 0.37-3.55, p = 0.6). Also stent/scaffold thrombosis did not differ between groups (1.2% in BRS group vs. 1.9% in DES group, p = 0.6). Occurrence of procedural-related myocardial injury was significantly higher in the BRS group (25% vs. 12%, p = 0.001), although it was not related to DOCE (HR 1.1, 95%CI 0.97-1.2, p = 0.2). Imaging techniques and enhanced stent visualization systems were significantly more employed in the BRS group (p = 0.0001 for both). Procedure length, fluoroscopy time and contrast dye amount were significantly higher in the BRS group (p = 0.001, p = 0.001 and p = 0.01, respectively). Conclusions Overlapping BRS utilization in long coronary lesions showed a comparable DOCE rate at 1 year if compared to second generation DES. Further and larger studies are on demand to confirm our findings.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0167527316301905-main.pdf
solo gestori archivio
Descrizione: Full text editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
357.32 kB
Formato
Adobe PDF
|
357.32 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.