A new ultra-high performance teicoplanin-based stationary phase was prepared starting from sub-2μm totally porous silica particles of narrow size distribution. Columns of different lengths were packed at high pressure and a deep and systematic evaluation of kinetic performance, in terms of van Deemter analysis, was performed under different elution conditions (HILIC, POM, RP and NP) by using both achiral and chiral probes. For the achiral probes, the efficiency of the columns at the minimum of the van Deemter curves were very high leading to some 278000, 270000, 262000 and 232000plates/m in hydrophilic interaction liquid chromatography (HILIC), polar organic mode (POM), normal phase (NP) and reversed phase (RP) respectively. The lowest plate height, Hmin=3.59μm (h(/)=1.89), was obtained under HILIC conditions at a flow rate of 1.4mL/min. Efficiency as high as 200000-250000plates/m (at the optimum flow rate) was obtained in the separation of the enantiomers of chiral probes under HILIC/POM conditions. N-protected amino acids, α-aryloxy acids, herbicides, anti-inflammatory agents were baseline separated on short (2-cm) and ultra-short (1-cm) columns, with analysis time in the order of 1min. The enantiomers of N-BOC-d,l-methionine were successfully baseline separated in only 11s in HILIC mode. Several examples of fast and efficient resolutions in sub/supercritical fluid chromatography were also obtained for a range of chiral carboxylic acids.
Ultra-fast high-efficiency enantioseparations by means of a teicoplanin-based chiral stationary phase made on sub-2 μm totally porous silica particles of narrow size distribution
Ismail, O. H.;CAVAZZINI, Alberto;
2016
Abstract
A new ultra-high performance teicoplanin-based stationary phase was prepared starting from sub-2μm totally porous silica particles of narrow size distribution. Columns of different lengths were packed at high pressure and a deep and systematic evaluation of kinetic performance, in terms of van Deemter analysis, was performed under different elution conditions (HILIC, POM, RP and NP) by using both achiral and chiral probes. For the achiral probes, the efficiency of the columns at the minimum of the van Deemter curves were very high leading to some 278000, 270000, 262000 and 232000plates/m in hydrophilic interaction liquid chromatography (HILIC), polar organic mode (POM), normal phase (NP) and reversed phase (RP) respectively. The lowest plate height, Hmin=3.59μm (h(/)=1.89), was obtained under HILIC conditions at a flow rate of 1.4mL/min. Efficiency as high as 200000-250000plates/m (at the optimum flow rate) was obtained in the separation of the enantiomers of chiral probes under HILIC/POM conditions. N-protected amino acids, α-aryloxy acids, herbicides, anti-inflammatory agents were baseline separated on short (2-cm) and ultra-short (1-cm) columns, with analysis time in the order of 1min. The enantiomers of N-BOC-d,l-methionine were successfully baseline separated in only 11s in HILIC mode. Several examples of fast and efficient resolutions in sub/supercritical fluid chromatography were also obtained for a range of chiral carboxylic acids.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S002196731501715X-main.pdf
solo gestori archivio
Descrizione: versione editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
4.51 MB
Formato
Adobe PDF
|
4.51 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
11392-2351262_postprint_cavazzini_alberto.pdf
accesso aperto
Descrizione: Post print
Tipologia:
Post-print
Licenza:
Creative commons
Dimensione
4.46 MB
Formato
Adobe PDF
|
4.46 MB | Adobe PDF | Visualizza/Apri |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.