The immunoassay is one of the most sensitive and reliable analytical techniques available in the clinical laboratory. The original label for immunoassays was radioisotopes, and these methods, radioimmunoassay (RIA) and immunoradiometric assay (IRMA) are still the reference methods, because of invulnerability of the radioactive emission with respect to environmental interference. Labels other than radioisotopes have been tested for use in immunoassay to improve the sensitivity and reliability and to avoid some of the disadvantages of radioisotopic techniques. New labels have continued to be developed (Horseradish peroxidase-HPR-, pyrophosphatase, luciferases, pyrodopirazines, europium cryptates, porphirins, phosphors) and new label detection methods have been set up (e.g. chemiluminescence assay, thermometric assay, NADP+ and FADP- based coupled assay). New immunoassay strategies such as simultaneous multianalyte automated test have been developed and the reliability of the assays has i...

How alternative are immunoassay systems employing non-radioisotopic labels? A comparative appraisal of their main analytical characteristis

GIGANTI, Melchiore;
1995

Abstract

The immunoassay is one of the most sensitive and reliable analytical techniques available in the clinical laboratory. The original label for immunoassays was radioisotopes, and these methods, radioimmunoassay (RIA) and immunoradiometric assay (IRMA) are still the reference methods, because of invulnerability of the radioactive emission with respect to environmental interference. Labels other than radioisotopes have been tested for use in immunoassay to improve the sensitivity and reliability and to avoid some of the disadvantages of radioisotopic techniques. New labels have continued to be developed (Horseradish peroxidase-HPR-, pyrophosphatase, luciferases, pyrodopirazines, europium cryptates, porphirins, phosphors) and new label detection methods have been set up (e.g. chemiluminescence assay, thermometric assay, NADP+ and FADP- based coupled assay). New immunoassay strategies such as simultaneous multianalyte automated test have been developed and the reliability of the assays has i...
1995
D., Pelizzola; E., Bombardieri; A., Brocchi; G., Cappelli; A., Coli; M., Ferdeghini; Giganti, Melchiore; M., Gion; G., Madeddu; M. I., Maussieri; P., ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1870321
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact