The authors tested a new equipment containing a phantom to check quality mammographic image and an electronic instrument to measure incident radiation (Phan-EX). The phantom contains objects which have similar characteristics to the details of diagnostic interest and allows an easy and accurate estimation of image quality on the basis of the number of objects detected. The radiation detector, consisting of a solid state photodiode, provides an integer proportional to the input exposure. The results obtained highlighted a good reproducibility of instrument output and a good relationship between these values and the exposure ones obtained with a much more expensive ionization chamber. The device response was linear in varying both the anodic exposure (mAs) and the x-ray tube voltage (varying the energy, the calibration factor varied only by a small percent). The authors conclude that the Phan-EX may be useful for quality assurance of the mammographic unit. Furthermore, they suggest some of its practical applications: daily tests of qualitative of the mammographic unit and the treatment system performance, control of the automatic exposure probe, choice and optimization of exposure and treatment of the film parameters, the determination of the output of the x-ray tube, the evaluation of the sensitivity of different screen/film systems
[Quality control of mammography: potential use of a new device for testing the image quality and the dose].
GAMBACCINI, Mauro;
1996
Abstract
The authors tested a new equipment containing a phantom to check quality mammographic image and an electronic instrument to measure incident radiation (Phan-EX). The phantom contains objects which have similar characteristics to the details of diagnostic interest and allows an easy and accurate estimation of image quality on the basis of the number of objects detected. The radiation detector, consisting of a solid state photodiode, provides an integer proportional to the input exposure. The results obtained highlighted a good reproducibility of instrument output and a good relationship between these values and the exposure ones obtained with a much more expensive ionization chamber. The device response was linear in varying both the anodic exposure (mAs) and the x-ray tube voltage (varying the energy, the calibration factor varied only by a small percent). The authors conclude that the Phan-EX may be useful for quality assurance of the mammographic unit. Furthermore, they suggest some of its practical applications: daily tests of qualitative of the mammographic unit and the treatment system performance, control of the automatic exposure probe, choice and optimization of exposure and treatment of the film parameters, the determination of the output of the x-ray tube, the evaluation of the sensitivity of different screen/film systemsI documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.