In this paper, two procedures for assessing water demand shortfalls following segment isolation are compared. The first (topological) procedure is based on a simple topological network analysis, and identifies the water demand shortfall as the water demand (under normal operational conditions) relative to the directly and/or indirectly isolated segment(s). The second (hydraulic) procedure is based on a pressure-driven hydraulic simulation of the network after segment isolation. Each of the two procedures was applied to two case studies, and the reliability (expressed in terms of maximum Dmax and weighted average D_ water demand shortfall) and economic burden (expressed in terms of number Nval or cost Cval of installed valves) of the resulting isolation valve system solution were compared. As a whole, the results show that network analysis and redesign are affected by the choice of the global variables (Dmax or D_) used to characterize the demand shortfalls in network segments. Analysis of the case studies is followed by a discussion of the rationale behind the choice between the two procedures, which needs to balance accurate demand shortfall characterization with limited computation times, particularly in the multi-objective design stage.

Evaluating water demand shortfalls in segment analysis

CREACO, Enrico Fortunato
Primo
;
FRANCHINI, Marco
Secondo
;
ALVISI, Stefano
Ultimo
2012

Abstract

In this paper, two procedures for assessing water demand shortfalls following segment isolation are compared. The first (topological) procedure is based on a simple topological network analysis, and identifies the water demand shortfall as the water demand (under normal operational conditions) relative to the directly and/or indirectly isolated segment(s). The second (hydraulic) procedure is based on a pressure-driven hydraulic simulation of the network after segment isolation. Each of the two procedures was applied to two case studies, and the reliability (expressed in terms of maximum Dmax and weighted average D_ water demand shortfall) and economic burden (expressed in terms of number Nval or cost Cval of installed valves) of the resulting isolation valve system solution were compared. As a whole, the results show that network analysis and redesign are affected by the choice of the global variables (Dmax or D_) used to characterize the demand shortfalls in network segments. Analysis of the case studies is followed by a discussion of the rationale behind the choice between the two procedures, which needs to balance accurate demand shortfall characterization with limited computation times, particularly in the multi-objective design stage.
2012
Creaco, Enrico Fortunato; Franchini, Marco; Alvisi, Stefano
File in questo prodotto:
File Dimensione Formato  
2010_WatResMan_Creaco.pdf

solo gestori archivio

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 456.63 kB
Formato Adobe PDF
456.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1681364
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 33
social impact