We have examined the complete set of X-ray afterglow observations of dark and optically bright gamma-ray bursts (GRBs) performed by BeppoSAX through 2001 February. X-ray afterglows are detected in ~90% of the cases. We do not find significant differences in the X-ray spectral shape, in particular no increased X-ray absorption in GRBs without optical transient (dark GRBs) compared to GRBs with optical transient (OTGRBs). Rather, we find that the 1.6-10 keV flux of OTGRBs is on average about 5 times larger than that of the dark GRBs. A Kolmogorov-Smirnov test shows that this difference is significant at 99.8% probability. Under the assumption that dark and OTGRBs have similar spectra, this could suggest that the first are uncaught in the optical band because they are just faint sources. In order to test this hypothesis, we have determined the optical-to-X-ray flux ratios of the sample. OTGRBs show a remarkably narrow distribution of flux ratios, which corresponds to an average optical-to-X-ray spectral index αOToX=0.794+/-0.054. We find that, while 75% of dark GRBs have flux ratio upper limits still consistent with those of OT GRBs, the remaining 25% are 4-10 times weaker in optical than in X-rays. The significance of this result is >=2.6 σ. If this subpopulation of dark GRBs were constituted by objects assimilable to OTGRBs, they should have shown optical fluxes higher than upper limits actually found. We discuss the possible causes of their behavior, including a possible occurrence in high-density clouds or origin at very high redshift and a connection with ancient, Population III stars.

A Comparative Study of the X-Ray Afterglow Properties of Optically Bright and Dark Gamma-Ray Bursts

FRONTERA, Filippo;
2003

Abstract

We have examined the complete set of X-ray afterglow observations of dark and optically bright gamma-ray bursts (GRBs) performed by BeppoSAX through 2001 February. X-ray afterglows are detected in ~90% of the cases. We do not find significant differences in the X-ray spectral shape, in particular no increased X-ray absorption in GRBs without optical transient (dark GRBs) compared to GRBs with optical transient (OTGRBs). Rather, we find that the 1.6-10 keV flux of OTGRBs is on average about 5 times larger than that of the dark GRBs. A Kolmogorov-Smirnov test shows that this difference is significant at 99.8% probability. Under the assumption that dark and OTGRBs have similar spectra, this could suggest that the first are uncaught in the optical band because they are just faint sources. In order to test this hypothesis, we have determined the optical-to-X-ray flux ratios of the sample. OTGRBs show a remarkably narrow distribution of flux ratios, which corresponds to an average optical-to-X-ray spectral index αOToX=0.794+/-0.054. We find that, while 75% of dark GRBs have flux ratio upper limits still consistent with those of OT GRBs, the remaining 25% are 4-10 times weaker in optical than in X-rays. The significance of this result is >=2.6 σ. If this subpopulation of dark GRBs were constituted by objects assimilable to OTGRBs, they should have shown optical fluxes higher than upper limits actually found. We discuss the possible causes of their behavior, including a possible occurrence in high-density clouds or origin at very high redshift and a connection with ancient, Population III stars.
2003
De, Pasquale; M., Piro; L., Perna; R., Costa; E., Feroci; M., Gandolfi; G., Zand; J. I. N. '. T., Nicastro; Frontera, Filippo; Antonelli, L. A.; And, ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1202263
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 84
  • ???jsp.display-item.citation.isi??? 83
social impact