Objective: Evaluation of the feasibility and utility of haemodynamic correction of primary varicose veins (French acronym: CHIVA). Design: Prospective, single patient group study. Setting: Department of Surgery, University of Ferrara, Italy (teaching hospital). Patients: Fifty-five patients with primary varicose veins and a normal deep venous system (ultrasonographic criteria) were studied. Interventions: Fifty-five haemodynamic corrections by the CHIVA method described by Franceschi were undertaken. Seven patients were treated for short saphenous vein varices (group A) while 48 patients were treated for long saphenous vein varices (group B). Main outcome measures: Clinical: presence of varices and reduction in symptoms. Duplex and continuous-wave Doppler detection of re-entry through the perforators and identification of recurrences or new sites of reflux. Postoperative ambulatory venous pressure and refilling time measurements. Patients were studied for 3 years following surgery. Res...

Hemodynamic correction of varicose veins (CHIVA): An effective treatment?

ZAMBONI, Paolo;FEO, Carlo;
1996

Abstract

Objective: Evaluation of the feasibility and utility of haemodynamic correction of primary varicose veins (French acronym: CHIVA). Design: Prospective, single patient group study. Setting: Department of Surgery, University of Ferrara, Italy (teaching hospital). Patients: Fifty-five patients with primary varicose veins and a normal deep venous system (ultrasonographic criteria) were studied. Interventions: Fifty-five haemodynamic corrections by the CHIVA method described by Franceschi were undertaken. Seven patients were treated for short saphenous vein varices (group A) while 48 patients were treated for long saphenous vein varices (group B). Main outcome measures: Clinical: presence of varices and reduction in symptoms. Duplex and continuous-wave Doppler detection of re-entry through the perforators and identification of recurrences or new sites of reflux. Postoperative ambulatory venous pressure and refilling time measurements. Patients were studied for 3 years following surgery. Res...
1996
Zamboni, Paolo; M. G., Marcellino; Feo, Carlo; C., Mari
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1201833
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact