Photovoltaic (PV) generation systems have become part of the electrical distribution networks due to their clean energy and adaptability. The increasing energy consumption and the several load types in the distribution network could produce voltage deviation. Therefore, there are some strategies, which are used to solve this problem, for example, capacitor banks, voltage regulators, transformer tap variation, static Var compensators, and reactive power exchange employing inverters. This article presents a smart inverter able to deliver and absorb reactive power through Volt-Var control to solve voltage deviations. The inverter compensates for voltage deviation in the primary transformer, whether inductive or capacitive loads are connected in the point of common coupling (PCC). In consequence, the inverter improves the voltage quality in the entire network. Finally, total harmonics percentage (THD) and frequency deviation have an acceptable performance during the operation, due to the inverter hardware configuration, and the phase-locked loop (PLL) implementation.

Control Strategy Applied to Smart Photovoltaic Inverters for Reactive Power Exchange Through Volt-Var Control to Improve Voltage Quality in Electrical Distribution Networks

Simani S.
Ultimo
Writing – Review & Editing
2022

Abstract

Photovoltaic (PV) generation systems have become part of the electrical distribution networks due to their clean energy and adaptability. The increasing energy consumption and the several load types in the distribution network could produce voltage deviation. Therefore, there are some strategies, which are used to solve this problem, for example, capacitor banks, voltage regulators, transformer tap variation, static Var compensators, and reactive power exchange employing inverters. This article presents a smart inverter able to deliver and absorb reactive power through Volt-Var control to solve voltage deviations. The inverter compensates for voltage deviation in the primary transformer, whether inductive or capacitive loads are connected in the point of common coupling (PCC). In consequence, the inverter improves the voltage quality in the entire network. Finally, total harmonics percentage (THD) and frequency deviation have an acceptable performance during the operation, due to the inverter hardware configuration, and the phase-locked loop (PLL) implementation.
2022
9789811641251
9789811641268
Converters, Microgrids, Power quality, Photovoltaic systems, Reactive power, control, Smart inverters, Volt-Var control
File in questo prodotto:
File Dimensione Formato  
2021 - paper_CITIS.pdf

solo gestori archivio

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.78 MB
Formato Adobe PDF
1.78 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
2022_Simani_CITIS.pdf

solo gestori archivio

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.4 MB
Formato Adobe PDF
2.4 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2501105
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact