This work presents the case study of the retrofitting of a historical building of the University of Padua, equipped with a hybrid heat pump system, which uses as heat source/sink the ground and ambient air. The building is located in Padua (Italy) and it is a historical complex of the late 1800, previously used as a geriatric hospital, in which a retrofit process is occurring in order to build the new humanistic campus of the Padua University reaching the highest energy efficiency. The refurbishment is in progress and regards both the building envelope and the plant-system. The building is equipped with two types of heat pumps: the first one is coupled to the ground with borehole heat exchangers and the second is a common air-to-water heat pump. The entire building plant system has been investigated through integrated computer simulations making use of EnergyPlus Software. A new control strategy in order to manage the two types of the heat pumps has been developed in order to increase the energy efficiency. The results outline the potential of the computer simulations in order to control the hybrid heat pump system. In fact, a suitable switch temperature was found in order to move from ground to air source/sink for the heat pumps. In addition, this strategy allows the control of the thermal drift of the ground temperature throughout the years.
Analysis of a double source heat pump system in a historical building
Emmi G.;
2020
Abstract
This work presents the case study of the retrofitting of a historical building of the University of Padua, equipped with a hybrid heat pump system, which uses as heat source/sink the ground and ambient air. The building is located in Padua (Italy) and it is a historical complex of the late 1800, previously used as a geriatric hospital, in which a retrofit process is occurring in order to build the new humanistic campus of the Padua University reaching the highest energy efficiency. The refurbishment is in progress and regards both the building envelope and the plant-system. The building is equipped with two types of heat pumps: the first one is coupled to the ground with borehole heat exchangers and the second is a common air-to-water heat pump. The entire building plant system has been investigated through integrated computer simulations making use of EnergyPlus Software. A new control strategy in order to manage the two types of the heat pumps has been developed in order to increase the energy efficiency. The results outline the potential of the computer simulations in order to control the hybrid heat pump system. In fact, a suitable switch temperature was found in order to move from ground to air source/sink for the heat pumps. In addition, this strategy allows the control of the thermal drift of the ground temperature throughout the years.File | Dimensione | Formato | |
---|---|---|---|
2019_Analysis of a double source heat pump system in a historical building.pdf
accesso aperto
Descrizione: versione editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
PUBBLICO - Pubblico con Copyright
Dimensione
6.55 MB
Formato
Adobe PDF
|
6.55 MB | Adobe PDF | Visualizza/Apri |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.