A procedure is here presented for near-optimal valve and hydrant activation scheduling in a water distribution system during a contamination event to minimize the water volume consumed by users. The constraints are represented by the number of response teams and the maximum speed at which these teams can move. The proposed procedure is based on a genetic algorithm (GA) that interacts with a mixed integer programming solver (MIP). The GA provides unconstrained operating times (in terms of speed), while the MIP solver modifies these times in order to satisfy the above-mentioned constraints while remaining as close as possible to their initial values. The optimization procedure is linked to a hydraulic and water quality simulator to calculate the amount of contaminated water consumed by users. The application of the procedure to a real and very complex water distribution system shows that the optimization process is robust and effective and reduces the impact of a contamination event on the population.

Near-optimal activation device scheduling to react to intentional or accidental contaminations in water distribution systems

ALVISI, Stefano
Primo
;
FRANCHINI, Marco
Secondo
;
GAVANELLI, Marco
Penultimo
;
NONATO, Maddalena
Ultimo
2010

Abstract

A procedure is here presented for near-optimal valve and hydrant activation scheduling in a water distribution system during a contamination event to minimize the water volume consumed by users. The constraints are represented by the number of response teams and the maximum speed at which these teams can move. The proposed procedure is based on a genetic algorithm (GA) that interacts with a mixed integer programming solver (MIP). The GA provides unconstrained operating times (in terms of speed), while the MIP solver modifies these times in order to satisfy the above-mentioned constraints while remaining as close as possible to their initial values. The optimization procedure is linked to a hydraulic and water quality simulator to calculate the amount of contaminated water consumed by users. The application of the procedure to a real and very complex water distribution system shows that the optimization process is robust and effective and reduces the impact of a contamination event on the population.
2010
9787122093141
water distribution systems; contamination; reaction; scheduling
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1402965
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact